1.
37th International Technical Conference on Circuits/Systems, Computers and Communications, ITC-CSCC 2022 ; : 514-517, 2022.
Article in English | Scopus | ID: covidwho-2097628

ABSTRACT

Article presents the development of the Airborne Infection Isolation Room (AIIR) thermal environmental control system. To support Covid-19 patients in the Airborne Infection Isolation Room (AIIR) Betong Hospital. The parameters to be controlled are according to the CDC and ASHRAE standard. Air pressure in the Isolation room <-mathbf{2}.mathbf{5}mathbf{Pa} Air Temperature Relative Humidity and Air Chang Rate are 21-24°C, 40-60%RH and 12 ACH respectively [1], [2]. The dehumidification system is a Desiccant wheel (DW) with diameters of 60 cm containing 3 kg of silica gel. The result of the measurement experimental in AIIR found that negative pressure-6.5 Pa average temperature relative humidity and air changes rate is 37.78°C 48.06 %RH and 16.57 ACH respectively. © 2022 IEEE.

2.
18th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, ECTI-CON 2021 ; : 733-736, 2021.
Article in English | Scopus | ID: covidwho-1369277

ABSTRACT

Indoor Temperature and relative humidity of the Airborne Infection Isolate Room (AIIR) are important factors that directly influence the transmission of airborne pathogens such as COVID-19 MERS SARS and tuberculosis. Also it affects the thermal comfort and health of doctors and nurses. This research aimed to measure and assess Indoor Air Quality (temperature relative humidity and humidity ratio) of the AIIRs. Additionally the energy consumption of the AIIR was located in the Pediatric Ward (AIIR-1) Internal Medicine Ward (AIIR-2) and Surgical Ward (AIIR-3). The study found that the Indoor Air Quality (temperature relative humidity and humidity ratio) of the AIIR-1 were 26.50 °C 78.96 % RH 17.22 k/kg.da respectively. The AIIR-2 had the means of 26.83 °C 78.41% RH 17.46 k/kg.da respectively. Finally the AIIR-3 had the means of 24.10 °C 78.92 % RH 14.79 k/kg.da respectively. Compared with the ASHRAE standard the analysis results found that the value was higher than the acceptable standards of ASHRAE STD 170 and ISO7730 (21-24 °C, 40-60% RH 12 g/kg.da). Average Energy consumption of AIIR-1 AIIR-2 and AIIR-3 were 0.67 kWh/h 0.68 kWh/h and 3.45 kWh/h respectively. © 2021 IEEE.

SELECTION OF CITATIONS
SEARCH DETAIL